Gas Furnace Blower Motor: Just like the name suggests, the blower motor controls the amount of heated air pushed through the air ducts to the spaces of your home. Follow the motor wires now and pay attention to where they are connected. If it does but the motor isn't running, then the blower motor has failed. In fact, more than 200 people die across the United States each year because of a problem with furnace ventilation in the home. You should check to see if power is reaching the motor. 01 - Blower Motor. First disconnect power to the furnace. The motor is located in the middle of the blower and is accessible from one side. A furnace inducer motor is essentially a motor-driven fan, with an electrical box for power connections and metal housing. If power is getting to the blower motor, but the motor does not run, the motor may be burned out. Blower Assembly Removal. The purpose of the motor is to move harmful gases including carbon monoxide out of your home through furnace vents or the chimney. Blower Motor: Your furnace's blower motor has either burnt itself out, or the connecting belt has snapped. Open the furnace door and locate the squirrel cage blower. First, make sure that power is getting to the motor. Disconnect the wires and now remove the complete blower housing. An aging, problematic, or dirty motor has to work harder to properly circulate conditioned air throughout your home, which leads to higher energy consumption. Sometimes it works sometimes it gets everything bound up to where you have to replace the blower wheel. Below are three blower motor options, each with an increasing level of comfort control. Common solutions for: Goodman Furnace blower not running. Single-Stage: A single-stage or single-speed option has two positions, ON or OFF. This is going to be on removing blower wheels from blower motors I see a lot of guys that will just get a fancy puller they won’t do any prep work on the motor shaft they’ll just drop their puller on there and try to remove it. Cut the wires going into the motor, as close to the motor as possible. Select the right blower motor for you from our massive stock of guaranteed genuine Goodman, Amana, and Janitrol OEM replacement blower motors. In the upflow/horizontal unit such as yours the removal is fairly simple. Your motor should move air through the furnace and heating vent pipes. Alternatively, if the motor does run, but the air still doesn't move, then the connecting belt has snapped. Do not cut any other wires in the compartment. The blower motor blows air through the return vent, past the heat exchanger, and into the home’s venting. As you flip through you will see the blower assembly. Goodman furnace troubleshooting blower motor replacement; Psychic seduction pdf; Even without the dangers of high voltage, you want to make sure you work on it correctly because furnaces can pose a danger. The blower motor is the part of your HVAC system that uses the most energy, so it may very well be the culprit if you see a significant rise in your utility bills. The blower motor is typically hidden behind the furnace's protective outside cover; it resembles a small barrel on its side with three wires extending from its housing. Once you unplug the wiring you will see the blower assembly either slides in the furnace on a track or the back edge sits up on a lip and the assembly secures to the middle of the chassis with a couple screws. Remove the blower compartment door to gain access to the motor. Most blower housings will be held in place with a couple of screws and then it will usually slide out. Turn off power to the furnace at the service panel.