One of the most overlooked issues is Power. Always check that your furnace is plugged into the wall outlet and turned on. 92-103343-01-00 VENDOR: CALVERT McBRIDE OR EQUIVALENT LABEL SIZE: 5.5” X 5.5” But then this winter the furnace began setting 13/33 codes. All rights reservedHot-water-heaters-reviews.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for us to earn fees by linking to Amazon.com and affiliated sites. Newer control units will either read “ready,” “on,” or “clear.” On every furnace with a diagnostic unit, there is a piece of paper taped to the inside of your removable panel. To clear fault code history, toggle dipswitch SW3-6 on/off three times. A year later it started throwing the code 13 again. I can see that if you don't have a screen, debris could get sucked in there and cause a similar problem. Household owners choose to twin turnaces when a large area needs to be heated, and there is no opportunity to install a large furnace. I … To determine if the igniter is faulty, remove the igniter and inspect it for cracks. If I read the ownerÂs manual correctly, I think itÂs saying that this is a "blower operating over RPM limits" code, with many different possible causes/solutions. There are Rheem furnaces, which can be ‘twinned’, i. e. used together and sharing a thermostat or duct network. Double checked the system and realized I had not reconnected the power to the small transformer attached to the gas system, located just to the right of the top right corner of the circuit board. Unlike many other furnaces, Rheem ones don't use flashing LED light sequences to indicate errors, and the display will instead give you a simple code you can use for diagnostics. Sure enough, one of them showed deposits and now we're back to operating reliably. CODE: 14 I have had those little transformers fail on devices over the years so if yours is giving the Error 13 after about 30 seconds, every time, that transformer may have failed. Service tech said it looks good may want to replace flame rods and he left (without putting the cover back on) sure enough I put a cover on and it has code 13 again. Ruud Ruud furnace review, prices, and model comparison. Rheem Manufacturing ranks as the global leader in the manufacture of high-quality, sustainable, and innovative water heaters, tankless water heaters, air conditioners, furnaces, pool heaters, and HVAC systems for residential and commercial applications, and is a full member of AHRI, the Air-Conditioning, Heating, & Refrigeration Institute. 13 Flame Lost 93 Internal Fault 14 Unexpected Flame Notes: 1. How? Some Rheem models particularly newer furnaces have an integrated furnace control inside them that flashes a warning LED light when there is a problem with operation. How? I had this 96% efficient furnace installed 6 years ago because I wanted to add an air conditioner and figured I would replace my 26 year old Rheem furnace that I had never had a single problem with. Our comprehensive Rheem Furnace error code guide will explain common issues, provide tips, and show you how to read your model's error codes. I cleaned the manifold but not the burners and reassembled. Also for: Rtg53, Rtg66, Rtg74, Svc 810. Rheem Furnace Repair Help. Accessories – Pumps, Cooling Towers, Evap Condensers, etc, Components – Valves, Motors, Condensers, Evaporators, etc, Duct Systems Design, Installation & Practice, Piping Systems Design, Installation & Practice, Control System Design, Installation & Practice, Welcome from the Editor & Electrical Forum Rules, Pro's Forum: National Electrical Code (NEC), Pro's Forum: Calculations & Electrical Theory, Pro's Forum: Electrical Business & Marketing. I told the little turd that I was 55 and I have been plumbing since I was 16. Rheem Rheem furnace review, prices, and model comparison. started. UPFLOW/HORIZONTAL SINGLE STAGE GAS FURNACES. If the igniter is cracked, replace it. Code 13/33 caused by high MERV filters. I have installed many tank & tankless water heaters as I am a plumber. The igniter gets very hot and glows bright orange to light the gas burner. Once I got past the original tech suggesting a multitude of lame reasons, I was transferred to a real tech who suggested examining the FLAME RODS (thermocouples) for deposits and use either steel wool or fine grit sandpaper to remove them if present. That was a bad mistake. Error Code 13: The flame was lost. 03:52. Add them up and you can see there is a problem if the dryer and stove are on when someone is showering do yourself a favor and see if this could also be your problem. Why doesn't Rheem offer an incoming air filter? Post photos, respond to polls and access other special features. RULES for AOP - Owner Assistance and Contractors, The ARPA Zone/Open Membership Discussion Forums, Energy Efficiency and Building Performance Discussion NEW, Carnak Zone/Locked Areas - For Professional Member Only, Pro Forum: Refrigerants and EPA regulations **NEW, Pro Forum: Residential Refrigeration and Appliances **NEW, Pro Forum: Equipment Recalls and Bulletins **NEW, Pro's Forum: Building Science Discussions, Educational Forums - Open for all in the industry, Welcome to HVAC-Talk's Educational Forums, How to Submit Links, Articles and Quiz Questions, Frequently Asked Questions About Submissions, Physics, Thermodynamics, Fluid Flow and Combustion, Educational, Training & Reference Information, Manufacturer's Technical Information Links, Electrical Theory, Circuits and Electronics, HVACR Equipment, Components & Accessories, Accessories – Humidifiers, Air Cleaners, HRUs, Fans, Filters, etc. The #1 question asked by NEW MEMBERS. rheem furnace codes. 228,322. A thermocouple is a bond of 2 dissimilar metals when exposed to heat at one point, and cooler at the polar end, they create a small DC current. After less than 3 years the flame sensor needed to be replaced which required a service call. View solutions. Wait 30 minutes if the furnace has shut off unexpectedly due to a power failure and then adjust the thermostat to the lowest setting. Featured Video. Not once did he tell me that codes 12 & 13 are a constant problem with these W/H. The brand also offers a great range of gas furnaces and different price points, with plenty of features to justify the higher prices in their Prestige Series. Common solutions for: Rheem Furnace not heating. View and Download Rheem 801S Series installation instructions manual online. Some of the troubleshooting tips that might save you time are as listed below. Error Code 20: There was a twinning fault. I have a Rheem RTGH 95-DVLN unit, that worked great for about 4 years. I cleaned the burner again; a lot of debris in it. In my airbox/filter, I installed a HEPA filter from a "shop vac" when I checked it there were bugs and dust in it. These tankless units appear to be over-engineered and prone to sensor issues after prolonged use which leaves consumers with a bad feeling about their unreliability. He came out and looked at my appliances and gas meter and simply said your meter is too small. Gas company came out and installed a 630000 meter no charge. RTG2-42 water heater pdf manual download. 1. Simply click here to return to Rheem. NOTE: If IFC goes into lockout (“STATUS LED will blink code “1”), shut off main power to unit, wait 30 seconds and then reset power. Error Code 22: Problem with high limit. To find your local Rheem Approved Plumber, contact us or call Rheem Service on 1300 556 036. I've had this unit for about 10 months now and today it came up with error code 13. CODE: 10 PROBLEM: There's a one-hour lockout in place. PROBLEM STILL PRESENT Fault Code Present Thanks for all of the advice above. Video. This time I built an airbox/filter for the incoming air. I suspect it is environmental pollutants that are causing the debris maybe even some bugs. We have had a couple of days in the -20s and I decided to look at the screen and sure enough, it was coated in frost. I took some pics but no way to upload them here. Tankless. I put a filter screen on the intake and it worked fine until now. Components – Coils, Heaters, Motors, etc. Error Code 12: Low flame detected. Power. 11 possible causes and potential solutions . … Then it started again, so I know that most problems are gas input thermocouples, diaphragm and so every 3 months I clean the burner, igniter and thermocouple. Rheem furnaces are all equipped with an advanced 7-segment diagnostic display you can use as a guide if something goes wrong with your heating system. Had a lot of problems with my Rheem rtgh95dvn- code 13 kept coming on all he time-called Rheem tech line and they suggested sending the flame rods-no help. Simply click here to return to. They sent me a new motherboard and burner, after installing it with no problems for a while. Our 20th year anniversary is May 21, 2020. Featured Video. Rheem Classic 90 Plus Furnace Troubleshooting. Tempstar Tempstar furnace review, prices, and model comparison. On older furnaces, a steady green light is usually the diagnostic sign for all-clear. Worked great all summer. It's easy to do. My Rheem has thrown a code 13 several times now. Cleaned the intake screen- it was filthy, and still had the code. This water heater started to be a problem, 6 months after I bought it. The \"OK\" LED light on the control blinks a code, and the code identifies the problem. 4 possible causes and potential solutions . Rheem Error Code What this means; Error Code 10: There's a one-hour lockout in place. Gain access to our free AOP (Ask a Professional) Section to get real answers for your questions. This piece of paper contains the glossary for diagnostic codes. The thermostat is still calling for heat when this happens so the fan stops, burners light again, fan comes on and then it works like it should and will heat until the end of the cycle with … I'm an HVAC tech and I too had this issue, did all the basics checked the vent stack, cleaned burner/flame sensors. Furnace may need an isolation relay. My Rheem Continuous Flow Water Heater is showing a fault code. Fault Codes 13 or 33 indicate a limit switch lockout. Furnace Error Code 13 for Carrier Bryant and Payne - YouTube Kudos to the Rheem technician (800-­432-­8373) for pointing me in the right direction. Two horizontal bars will be displayed for 4 sec. Furnace is noisy or loud. Yes... we are 20 years old. When I told them, I installed it and I was told that's where the problem could be. 820. Last summer, to help with allergies, we replaced all our filters (4 returns 12x12 and the 14x20 HVAC) with high MERV Filters. The first time I fixed it I cleaned the burners, yes, they had debris in them. 62-104058-02 - OEM Upgraded Replacement for Rheem Furnace Control Board: Amazon.com: Industrial & Scientific It gradually became more frequent. Reconnected the power and everything works perfectly. Join in and write your own page! Error Code 14: There was an unexpected flame. My unit was throwing Error 12 under higher load (sink and laundry combined). Then the infamous Code 13 came up about 3-4 months ago. Fault code history displayed at power up - most recent fault displayed first. At the end of the job they tested all gas fired appliances as they had the main gas off to preform this job, and made sure everything was working proper. Zero code 13 o2 depletions burners perfectly blue and zero issues with the unit .. Hope this helps you solve this Rheem phantom issue. The codes are described taking into account the code itself, its status, technical details and possible solutions of the problem. Most Common Problems. Please see the Owner's Guide for your Continuous Flow Water Heater model. Other Light Codes. A year later it started throwing the code 13 again. Rheem gas furnaces are a great choice thanks to their reliability and long term warranty options. Error Code 26: Reversal of line and neutral. I went out and saw my meter was a 250000btu meter. CODE: 13 PROBLEM: The flame was lost. Ask Our Pros-Owner Assistance - NO DIY advice will be given. I greatly suspect examining and cleaning the FLAME RODS would solve the majority of code "13" issues. After 1 year of flawless operation we began experiencing sporadic "13" error codes causing us to reset 1-2 times per day. Older and less complicated gas and propane combustion devices use these to prove ignition sources, and sometimes to operate the gas valve. Accessing them inside of the tankless unit is not as simple, but proved just as effective. This time I built an airbox/filter for the incoming air. I cleaned it off with a broom and so far it seems to have corrected the problem. Rheem Manufacturing ranks as the global leader in the manufacture of high-quality, sustainable, and innovative water heaters, tankless water heaters, air conditioners, furnaces, pool heaters, and HVAC systems for residential and commercial applications, and is a full member of AHRI, the Air-Conditioning, Heating, & Refrigeration Institute. CODE: 11 PROBLEM: The ignition failed. - Check installation instructions under section titled “Isolation Relay” for details .-Verify correct furnace sizing. Still, code 13, Rheem was no help all gas pressure was normal, what I noticed after a small power surge the code 13 issue came about but nothing changed, well something did the setting in the plc/ board. Rheem R801TA050314MSA - Classic Plus 80% Gas Furnace, Single Stage, 50K BTU, Upflow/Horizontal, X-13 Motor, Up to 3 Ton Skip to the end of the images gallery Skip to the beginning of the images gallery I started getting code 13, tried sanding flame rod put the cover back on and it had code 13 again, called service tech pulled the cover off again and it started working. Furnace not heating. Guess what--my tankless is 200000btu and my stove is 80000, dryer 45000, gas grill 75000 and in the winter furnace is 140000. What is happening is the call for heat comes on, burners ignite, fan kicks on, and 2-3 mins later the burners go out and the control board shows status code 13 which means flame lost. I was told to check the flue, gas, is it plugged in, who installed it. 2. If this code is present, verify that the blower runs for ninety seconds before the furnace starts a normal heating cycle. Fault Code 12 indicates a power interruption on the furnace powered up during a call for heat. - Furnace repair service heating installation HVAC ac repair heating rebate Hot Water Tanks, Boilers BC Furnace Vancouver Burnaby Surrey Coquitlam Richmond It's easy to do. Mostly the detailed … 801S Series furnace pdf manual download. View solutions. I have a Rheem RGFD modulating furnace and it is displaying a flashing 66 LED code. Copyright. Called back and they gave me the number of a Rheem tech in my area. Need help finding your model number? I've had to clean them with my furnace every few years and found them more accessible and a simple fix. CODE: 12 PROBLEM: Low flame detected. This applied to furnaces of the same model and make. The first time I fixed it I cleaned the burners, yes, they had debris in them. Rheem, a furnace and home appliance manufacturer based in California, produces a line of furnaces for home use. Search Help by Model. Code 13 by: LD My Rheem has thrown a code 13 several times now. 01 - Igniter. Participate in over 40 different forums and search/browse from nearly 3 million posts. Please follow this Rheem Classic 90 Plus troubleshooting guide to fix common problems. If the igniter fails or cracks, the furnace won’t heat. :). I called the helpline and that's where the B.S. Rheem Manufacturing ranks as the global leader in the manufacture of high-quality, sustainable, and innovative water heaters, tankless water heaters, air conditioners, furnaces, pool heaters, and HVAC systems for residential and commercial applications, and is a full member of AHRI, the Air-Conditioning, Heating, & Refrigeration Institute. The unit then started throwing error 13 after about 30 seconds under any load. The flame probes are NOT thermocouples. KDM did a very professional job paying attention to safety and TSSA codes for this type of work. Error Code 11: The ignition failed. View and Download Rheem RTG2-42 troubleshooting manual online. Join in and write your own page!